Maintenance and Service for Ventilation Systems

Maintenance of ventilation systems
for clean air in your rooms.

Maintenance of
ventilation systems
for clean air
in your rooms.

Service, remediation of defects, hygiene per VDI 6022
and fire protection for your ventilation system.

Service, remediation of defects,
hygiene per VDI 6022
and fire protection for
your ventilation system.

Your ventilation system should deliver clean air and must not transfer fire or smoke to other fire zones in the event of a fire.
Anyone operating such a system must maintain it properly and be able to provide proof of this.
We handle all work on the system, from maintenance and deficiency reports to fire dampers.

Maintenance, filter replacement
and cleaning

Maintenance, filter replacement and cleaning

The performance of a ventilation system usually declines gradually. If filters become clogged, pressure loss increases. Then, either less air reaches the rooms, or the fan requires more power to maintain the air volume.

During the maintenance of your ventilation system, we replace the filters, clean the housing and coils, and inspect fans, drives, and controls. A slipping V-belt or a bearing that becomes noisy is often noticed before the system comes to a standstill.

Lorenzen Kältetechnik employee working overhead on an open ceiling cassette with fan wheel
Two Lorenzen Kältetechnik employees talking at the window front in the office

Support for inspections
by TÜV or DEKRA

Support for inspections by TÜV or DEKRA

We are there for you regarding all aspects of your ventilation system inspection by TÜV or DEKRA. The inspection itself is carried out by the experts; we take care of what needs to be done on the system afterward.

The process often concludes with a deficiency report. It records what was flagged, such as a fire damper that does not close completely. The report usually does not state the cause of a defect, and sometimes several points are related. We find that out for you.

Remediation of defects
and troubleshooting

Remediation of defects and troubleshooting

We work through your deficiency report point by point. Some issues are resolved quickly; for others, we first search for the root cause. If the required air volume does not reach a room, it could be due to the controls, a jammed damper, or a leak in the ductwork.

We only replace a component once it is certain that the fault lies there. We are open with you about what we find. We want your system to remain in good working order afterward, not just until the next inspection.

Grey two-level air handling unit with insulated extract and supply air duct connections in a plant room
Blue air handling unit with access doors, round inspection windows and actuators in a plant room

Hygiene inspection
according to VDI 6022

Hygiene inspection according to VDI 6022

Dust, pollen, and moisture enter the system with the outside air. Wherever these settle, germs can grow and enter the rooms with the supply air. The operator of a ventilation system must be able to prove its hygienic condition.

We determine this condition with a hygiene inspection according to VDI 6022. In doing so, we check the areas where dirt and moisture can collect, such as the outside air intake, filters, heat exchangers, humidifiers, and condensate trays. We document the results so you have the proof in hand.

“

We ask questions because we
want to understand the system.

We ask questions because we
want to understand the system.

Christian Lorenzen
Christian Lorenzen

Testing and maintaining
fire dampers

Testing and maintaining fire dampers

Where a ventilation duct passes through a wall or ceiling with fire protection requirements, such as between two fire zones or floors, a fire damper is usually installed. In the event of a fire, it closes and prevents fire and smoke from spreading through the duct. This only works if it moves freely and triggers as soon as necessary.

Therefore, we trigger the damper during the functional test and check whether it closes completely and can be opened again afterward. If a damper is stiff or dirty, we repair it. If it is damaged or if repairs no longer help, we replace it.

A male and female employee of Lorenzen Kältetechnik discuss a floor plan at the meeting table
Inside the fan section of an air handling unit: electric motor on its mounting bracket, with a variable frequency drive on the casing wall

Optimization and
a holistic view of the system

Optimization and a holistic view of the system

During maintenance and service, we also see where your system could work better. If it runs at times when no one is in the building, or if it moves more air than the rooms need, we will bring it up. You decide whether and which optimization is worthwhile.

Many ventilation systems receive their cooling via a cooling coil from a chiller. This refrigeration technology is the core of our work. If both are connected, we look at ventilation and cooling together. We operate mainly in Lübeck and Hamburg, as well as in Kiel, Bad Oldesloe, and Ahrensburg; further distances by arrangement. If you have a deficiency report on your desk or the next maintenance is due, please contact us.

An excerpt of our work & projects

An excerpt of our
work & projects

Refrigeration and air conditioning technology where it has to work.

Refrigeration and air conditioning technology where
it has to work.

Refrigeration Technology Lübeck

Request a free quote now

Yes, I have read the privacy policy and agree that my details and data will be collected and stored electronically to answer my inquiry. You can revoke your consent at any time for the future by emailing mail@lo-lo.de.